- Amplifiers[1]
- Other Audio & Video Equipments[1]
- Connectors[10]
- Control Cables[5]
- Electrical Wires[10]
- Other Wiring Accessories[1]
- Testing Equipment[2]
- CCTV Camera[10]
- CCTV DVR[2]
- CCTV System[1]
- Other Surveillance Products[4]
- Communication Cables[10]
- Fiber Optic Equipment[10]
- Other Telecommunications Products[6]
- Telecom Parts[9]
- Other Hand Tools[10]
Security RG59 Coaxial Cable
1.BC Conductor, RG59
2 Insulation: Foam PE
3.Single or double shielded
4.Security RG59 Coaxial Cable
Security RG59 Coaxial Cable
Applications:
Used in communication and signal control systems
Reference Standards:
MIL-C-17D
Constructions
Conductor: Bare Copper
Insulation: PE or Foam PE
Double Layers Shield: AL-Foil + Bare Copper
Four Layers Shield: AL-Foil + Bare Copper + AL-Foil + Bare Copper
Jacket: PVC
Specifications
Picture
| Model No. | Specifications | Unit | |||
RG Series Coaxial Cable
| ||||||
AP-RG59 | 1/0.64mm BC Conductor +3.7mm PE Insulation +96/0.11mm,BC Braiding ( 80% coverage)+6.0mm PVC Jacket | m |
General Specifications | |
Model No. | AP-RG59 |
Application | Security CCTV |
Cable Type | Series 59 |
Jacket Color | Black |
Center Conductor Gauge | 22AWG (0.64mm) |
Center Conductor Type | Solid |
Packaging Type | Box 305 m (1000 ft) |
Environmental Specifications | |
Temperature Rating | 60 °C (140 °F) |
Construction Materials and Dimensions | |
Construction Type | Non-armored |
Center Conductor Material | Bare copper |
Diameter Over Center Conductor | (0.81 mm) 0.64mm per 1 strand |
Dielectric Material | (Foam) PE |
Diameter Over Dielectric | 3.43 mm (0.1350 in) 3.7mm |
Shield (Braid) Coverage | 95 % 80% |
Shield (Braid) Gauge | 36 AWG 37AWG |
Shield (Braid) Material | Bare copper |
Diameter Over Shield (Tape) | 4.089 mm (0.161 in) |
Jacket Material | PVC |
Diameter Over Jacket | 4.902 mm (0.193 in) 6.0mm |
Diameter Over Jacket Tolerance | ±0.006 in |
Jacket Thickness | 0.406 mm (0.016 in) |
Jacket Thickness, minimum spot | 0.279 mm (0.011 in) |
Electrical Specifications | |
Capacitance | 52.5 pF/m (16.0 pF/ft) |
Characteristic Impedance | 75 ohm |
Characteristic Impedance Tolerance | ±3 ohm |
Conductor dc Resistance | 10.50 ohms/kft |
Dielectric Strength, conductor to shield | 2500 Vdc |
Jacket Spark Test Voltage | 2500 Vac |
Nominal Velocity of Propagation (NVP) | 84 % |
Shield dc Resistance | 2.70 ohms/kft |
Structural Return Loss | 20 dB @ 10–300 MHz |
Structural Return Loss Test Method | 100% Swept Tested |
Performance
Frequency | Attenuation (dB/100 ft) |
1 MHz | 0.30 |
10 MHz | 0.86 |
50 MHz | 1.91 |
100 MHz | 2.78 |
200 MHz | 4.06 |
400 MHz | 6.01 |
700 MHz | 8.47 |
900 MHz | 9.82 |
1000 MHz | 10.47 |